Luminous Efficiency Functions Spectral Power Distributions
Defines various luminous efficiency functions involved in spectral
computations.
The luminous efficiency data is in the form of a dict of
colour.colorimetry.spectrum.SpectralPowerDistribution classes as
follows:
{'name': SpectralPowerDistribution, ..., 'name': SpectralPowerDistribution}
The following luminous efficiency functions are available:
- CIE 1924 Photopic Standard Observer
- Judd Modified CIE 1951 Photopic Standard Observer
- Judd-Vos Modified CIE 1978 Photopic Standard Observer
- CIE 1964 Photopic 10 Degree Standard Observer
- CIE 2008 2 Degree Physiologically Relevant LEF
- CIE 2008 10 Degree Physiologically Relevant LEF
- CIE 1951 Scotopic Standard Observer
Notes
References
-
colour.colorimetry.dataset.lefs.PHOTOPIC_LEFS = CaseInsensitiveMapping({u'CIE 1924 Photopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aeddd0>, u'CIE 1964 Photopic 10 Degree Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede90>, u'Judd-Vos Modified CIE 1978 Photopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede50>, u'cie_10_1964': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede90>, u'Judd Modified CIE 1951 Photopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede10>, u'CIE 2008 10 Degree Physiologically Relevant LEF': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aedf10>, u'CIE 2008 2 Degree Physiologically Relevant LEF': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aeded0>, u'cie_2_1924': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aeddd0>})
Photopic luminous efficiency functions.
- PHOTOPIC_LEFS : CaseInsensitiveMapping
- {‘CIE 1924 Photopic Standard Observer’,
‘Judd Modified CIE 1951 Photopic Standard Observer’,
‘Judd-Vos Modified CIE 1978 Photopic Standard Observer’,
‘CIE 1964 Photopic 10 Degree Standard Observer’,
‘CIE 2008 2 Degree Physiologically Relevant LEF’,
‘CIE 2008 10 Degree Physiologically Relevant LEF’}
Aliases:
- ‘cie_2_1924’: ‘CIE 1931 2 Degree Standard Observer’
- ‘cie_10_1964’: ‘CIE 1964 Photopic 10 Degree Standard Observer’
-
colour.colorimetry.dataset.lefs.SCOTOPIC_LEFS = CaseInsensitiveMapping({u'cie_1951': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aedf90>, u'CIE 1951 Scotopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aedf90>})
Scotopic luminous efficiency functions.
- SCOTOPIC_LEFS : CaseInsensitiveMapping
- {‘CIE 1951 Scotopic Standard Observer’,}
Aliases:
- ‘cie_1951’: ‘CIE 1951 Scotopic Standard Observer’
-
colour.colorimetry.dataset.lefs.LEFS = CaseInsensitiveMapping({u'CIE 1924 Photopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aeddd0>, u'CIE 1964 Photopic 10 Degree Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede90>, u'cie_1951': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aedf90>, u'Judd-Vos Modified CIE 1978 Photopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede50>, u'cie_10_1964': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede90>, u'Judd Modified CIE 1951 Photopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aede10>, u'CIE 1951 Scotopic Standard Observer': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aedf90>, u'CIE 2008 10 Degree Physiologically Relevant LEF': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aedf10>, u'CIE 2008 2 Degree Physiologically Relevant LEF': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aeded0>, u'cie_2_1924': <colour.colorimetry.spectrum.SpectralPowerDistribution object at 0x2b3679aeddd0>})
Aggregated luminous efficiency functions.
- LEFS : CaseInsensitiveMapping
- {‘CIE 1924 Photopic Standard Observer’,
‘Judd Modified CIE 1951 Photopic Standard Observer’,
‘Judd-Vos Modified CIE 1978 Photopic Standard Observer’,
‘CIE 1964 Photopic 10 Degree Standard Observer’,
‘CIE 2008 2 Degree Physiologically Relevant LEF’,
‘CIE 2008 10 Degree Physiologically Relevant LEF’,
‘CIE 1951 Scotopic Standard Observer’}
-
colour.colorimetry.dataset.lefs.MESOPIC_X_DATA = {1.0: CaseInsensitiveMapping({u'Red Heavy': CaseInsensitiveMapping({u'LRC': 1.0, u'MOVE': 0.68}), u'Blue Heavy': CaseInsensitiveMapping({u'LRC': 1.0, u'MOVE': 0.7})}), 10: CaseInsensitiveMapping({u'Red Heavy': CaseInsensitiveMapping({u'LRC': 1.0, u'MOVE': 0.98}), u'Blue Heavy': CaseInsensitiveMapping({u'LRC': 1.0, u'MOVE': 0.98})}), 0.1: CaseInsensitiveMapping({u'Red Heavy': CaseInsensitiveMapping({u'LRC': 0.11, u'MOVE': 0.34}), u'Blue Heavy': CaseInsensitiveMapping({u'LRC': 0.28, u'MOVE': 0.42})}), 0.01: CaseInsensitiveMapping({u'Red Heavy': CaseInsensitiveMapping({u'LRC': 0.01, u'MOVE': 0.0}), u'Blue Heavy': CaseInsensitiveMapping({u'LRC': 0.04, u'MOVE': 0.13})})}
Weighting factors for the mesopic luminous efficiency function calculation.
MESOPIC_X_DATA : CaseInsensitiveMapping